Specification
NAS Scaling: 1–24 nodes (12 HA pairs)
Maximum drives (HDD/SSD): 5,760/5,760
Maximum capacity: 57PB
Maximum onboard NVMe Flash CacheTM: 48TB
Maximum Flash PoolTM capacity: 576TB
Maximum memory: 3072GB
SAN Scaling: 1–12 nodes (6 HA pairs)
Maximum drives: 2,880/2,880
Maximum capacity: 28PB
Maximum onboard NVMe Flash CacheTM: 24TB
Maximum Flash Pool capacity: 288TB
Maximum memory: 1536GB
Cluster interconnect: 2 10GbE
Maximum drives (HDD/SSD): 480/480
Maximum capacity: 4.8PB
Controller form factor: Single-enclosure HA; 2 controllers in single 3U chassis
Memory: 256GB
Maximum onboard NVMe Flash CacheTM: 4TB
Maximum Flash Pool capacity: 48TB
Combined flash total 48TB
NVRAM: 16GB
PCIe expansion slots: 4
Onboard I/O: UTA2n (8Gb/16Gb FC, GbE/10GbE, or FCVI ports [MetroCluster only]): 8
Onboard I/O: 10GbE: 4
Onboard 10GbE Base-T: 4
Onboard I/O: 12Gb SAS: 8
Storage networking supported: FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB
OS version: ONTAP® 9.1
RC1 or higher
High-availability features: Ethernet-based service processor and ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies.
Supported Configurations ONTAP 9.1 or higher
Hardware cluster configurations:
- Two-node switchless or switched cluster
- Clusters of HA pairs
MetroCluster configurations for synchronous replication:
- 2-node
- 4-node: two x 2-node switched or switchless clusters with fabric-attached (switched) storage; 4 nodes total: a 2-node active-active cluster at each site)
- 8-node (NAS-only): four x 2-node switched or switchless clusters with fabric-attached (switched) storage; 8 nodes total: a 4-node cluster at each site)
Maximum RAID group sizes:
RAID-TEC™ (triple parity)
- SSDs and Performance HDDs: 29 (26 data disks plus 3 parity disks)
- Capacity HDDs: 29 (26 data disks plus 3 parity disks)
RAID 6 (RAID-DP®)
- SSDs and Performance HDDs: 28 (26 data disks plus 2 parity disks)
- Capacity HDDs: 20 (18 data disks plus 2 parity disks)
RAID 4
- SSDs and Performance HDDs: 14 (13 data disks plus 1 parity disk)
- Capacity HDDs: 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror®)
Operating systems supported: Windows® 2000, Windows Server® 2003, Windows Server 2008, Windows Server 2012, Windows Server 2016, Linux®, Oracle® Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX®
Max. number of LUNs: 12,288
Number of supported SAN hosts: 8,192
FlexVol® volumes: Up to 1,000 per controller
Snapshot® copies: Up to 255,000 per controller
Maximum volume size: 100TB
Maximum aggregate size: 400TB
MAXIMUM PORT COUNT
FC target ports (32Gb autoranging): 8
FC target ports (16Gb autoranging): 24
FC target ports (4Gb or 8Gb): 16
FCoE target ports, UTA (max.): 24
40GbE 8
10GbE ports (max.): 24
10GbE Base-T ports (max.): 4
6Gb/12Gb SAS ports (max.): 24
FC initiator ports (max.): 24
Maximum Adapters
32Gb FC 4
40GbE 4
Dual 10GbE (optical or copper) 4
Dual 10Gbase-T (RJ-45,CAT 6A-E) 4
Quad GbE (copper) 4
Dual 10GbE/FCoE 16Gb FC Unified Target Adapter 2 (UTA2, optical or copper for 10GbE/FCoE deployments, optical for 16Gb FC) 4
8Gb FC target 4
Quad 12Gb SAS storage HBA 4
Quad 4Gb FC storage/tape HBA (fiber) 4
Thermal Rating (at 200V)
1,850 BTU (typical)
2,130 BTU (worst case)
Power supply / cooling fans: Dual, hot pluggable, integrated power supply/fan assemblies
AC input power voltage (autoranging, VRMS): 100-120V, 200-240V
AC input power frequency: 50-60 Hz
Weight: 78.92 lbs
Depth: 19" (48 cm)